Catalog & Support

  • Instrumentation & Services

    Find Products, Service Centers, Dealerships, Manuals, and more.

  • Business Services

Companies & Community

  • Company
  • Industry Forums
  • T&M Job Bank (Openings)

Classifieds

  • Products & Services
  • Assets for Share/Rent
  • Trade-Ins & Deals
  • Donations & Recycle
  • Books

    Offered

    Wanted

Support

  • Product Documentation
  • Training
  • Techniques & Solutions
  • Product & Service Advisor

Resources

Social

  • Forums
  • Global Event Calendar
  • Frequently Asked Questions

____ This section requires a Corporate membership ____

Products & Services Wanted

  • Products & Related Services
  • Trade-Ins
  • Donations & Recycle
  • Open Solicitations - Products
  • Open Solicitations - Services

Mergers & Acquisitions

  • Offered
  • Wanted

Collaboration

  • Collaboration Offered
  • Collaboration Wanted
  • Sales Channels Offered
  • Sales Channels Wanted
  • T&M Job Bank (Resumes)
Stacks Image 89137

Materials Industry - Support

47
  • Search Measurement Standards

Found

Details

LM-85-14
IES Approved Method for Electrical & Photometric Measurements of High Power LEDs
LM-9-09
Electrical and Photometric Measurements of Fluorescent Lamps
LM-46-04
Photometric Testing of Indoor Luminaires Using High Intensity Discharge or Incandescent Filament Lam
LM-52-03
Photometric Measurements of Roadway Sign Installations (Reaffirmed 2014)
LM-62-06
Laboratory or Field Thermal Measurements of Fluorescent Lamps and Ballasts in Luminaires, Reaffirmed
LM-73-04
Testing of Entertainment Luminaires Using Incandescent Filament Lamps or High Density Discharge Lamp
LM-76-02
Photometric Testing of Fiber Optics Lighting Systems (Reaffirmed 2008)
LM-78-07
Approved Method for Total Luminous Flux Measurement of Lamps Using an Integrating Sphere Photometer
LM-79-08
Approved Method: Electrical and Photometric Measurements of Solid-State Lighting Products
LM-77-09
Intensity Distribution Measurement of Luminaires and Lamps Using Digital Screen Imaging Photometry
LM-81-10
Photometric Testing of Skylights and Tubular Daylighting Devices under Hemispherical Sky Conditions
LM-40-10
Life Testing of Fluorescent Lamps
LM-47-12
IES Approved Method For Life Testing of High Intensity Discharge (HID) Lamps
LM-49-12
Life Testing of Incandescent Filament Lamps
LM-51-13
Electrical and Photometric Measurement of High Intensity Discharge Lamps
LM-58-13
IES Approved Method for Spectroradiometric Measurement Methods for Light Sources
LM-84-14
IES Approved Method for Measuring Luminous Flux and Color Maintenance of LED Lamps, Light Engines, a
LM-41-14
Approved Method for Photometric Testing Of Indoor Fluorescent Luminaires
LM-66-14
Electrical and Photometric Measurements of Single-Based Fluorescent Lamps
LM-65-14
IES Approved Method for Life Testing of Single-Based Fluorescent Lamps
LM-80-15
IES Approved Method: Measuring Luminous Flux and Color Maintenance of LED Packages, Arrays and Modul
LM-45-15
IES Approved Method for the Electrical and Photometric Measurement of General Service Incandescent F
IEC 61000-4-16
Electromagnetic compatibility (EMC) - Part 4-16: Testing and measurement techniques - Test for immunity to conducted, common mode disturbances in the frequency range 0 Hz to 150 kHz.
ITU G650.3
Definitions and test methods for installed single mode fiber cable sections
EIA/TIA-455-FOTP-33
Fiber Optic Cable Tensile Load and Bending
EIA/TIA-455-FOTP-111
Vibration Test Procedure for Fiber Optic Components and Cables
EIA/TIA-455-FOTP-195
Coating Geometry Measurement for Optical Fiber
MIL-DTL-38999
General Specifications for Electrical Circular Connectors
IEC 60793-1-48
Measurement Methods and Test Procedures: Polarization Mode Dispersion
IEC 60793-2-50 (C5)
Measurement methods and test procedures: Hydrogen Aging
First 1 of 2 Last Show: 10, 20, 30, All
LM-77-09
01-Jan-2009
Intensity Distribution Measurement of Luminaires and Lamps Using Digital Screen Imaging Photometry
The intent of LM-77-09 is to describe measurement procedures for the determination of the luminous intensity distribution of certain lamps and luminaries using a digital camera to capture the projected light distribution from a luminaire on a screen.  This measurement technique is relatively new, therefore considerable detail is provided to assist the reader in understanding the principles, requirements and limitations involved.  Digital photometry offers very high speed data collection over a traditional goniophotometer, although typically over a restricted angular range.  Many factors must be taken into account to achieve accurate digital photometry and this report addresses the most significant of these factors.
 

Contents

1  Foreword

2  Background and Basic Principles 

3  Test System Geometry

4  Angular Resolution

5  Stray Light

6  Specification of the Digital Camera

7  Linearity Verification and Useable Range 

8  Calibration 

9  Test Procedure 

10 Data Reduction and Test Report 

References 

Glossary 

ANNEX A Geometrical Relationships 

ANNEX B—Lens Distortion Correction 

ANNEX C—Noise Estimation 

ANNEX D—Linearity Calculation Details

All Registered Trademarks, brand names and logos are respected and their ownership acknowledged. They are used on this website for information and reference purposes only. Test Interest doesn't assume any other implication or representation.

TI-IND-MAT-6-3